ReliaCloud Edge On-Premise GPC Nodes

As the name suggests, ReliaCloud Edge On-Premise General Performance Compute (GPC) nodes are configured to be able to run most workloads. These are ideal for most starter environments with a low density of VMs. Being outfitted with a mix of both solid state and traditional hard drives makes these nodes suitable for disaster recovery as well.

RELIACLOUD EDGE ON-PREMISES GPC NODES

Model ReliaCloud EDGE
GPC.1207F
ReliaCloud EDGE
GPC.1615F
ReliaCloud EDGE
GPC.2407H
ReliaCloud EDGE
GPC.3215H
ReliaCloud EDGE
GPC.3230F
Price Per Node (AHV) Reserved/ Activated Monthly $1130
$220/$1130
$1400
$270/$1400
$2020
$470/$2020
$2850
$750/$2850
$3180
$870/$3180
Chassis/Model Nutanix NX-G8 1175s Nutanix NX-G8 1175s Nutanix NX-G8 8155N Nutanix NX-G8 8155N Nutanix NX-G8 8155N
Processor 1 x Intel Xeon-Gold 5317 Processor (3Ghz/ 12-core/ 150w) (12 cores) 1 x Intel Xeon-Gold 6326 processor (2.9 GHz/ 16-core/ 185W) (16 Cores) 2 x Intel Xeon-Gold 5317 Processor (3Ghz/ 12-core/ 150w) (24 cores) 2 x Intel Xeon-Gold 6346 processor (3.1 GHz/ 16-core/ 205W) (32 Cores) 2 x Intel Xeon-Gold 6346 processor (3.1 GHz/ 16-core/ 205W) (32 Cores)
RAM 256 GB – 4 X 64 GB
Memory Module (3200MHz DDR4 RDIMM)
512 GB – 8 x 64GB Memory Module (3200MHz DDR4 RDIMM) 512 GB – 16 x 32GB Memory Module (3200MHz DDR4 RDIMM) 1024 GB – 32 x 32GB Memory Module (3200MHz DDR4 RDIMM) 1024 GB – 32 x 32GB Memory Module (3200MHz DDR4 RDIMM)
SSD/NVMe 7.68 TB – 4 x 1.92 TB SSD 15.36 TB – 4 x 3.84 TB SSD 7.68 TB – 2 x 3.84 TB SSD 15.36 TB – 4 x 3.84 TB SSD 30.72 TB – 4 x 7.68 TB SSD
HDD None None 24 TB – 4 x 6 TB HDD 48 TB – 6 x 8 TB HDD 64 TB – 8 x 8 TB HDD
NIC 1 x Mellanox 25/10GbE 2-port (CX6 25GbE) 1 x Mellanox 25/10GbE 2-port (CX6 25GbE) 1 x Mellanox 25/10GbE 2-port (CX6 25GbE) 1 x Mellanox 25/10GbE 2-port (CX6 25GbE) 1 x Mellanox 25/10GbE 2-port (CX6 25GbE)
GPU None None None None None

Hosting Requirements

Model GPC.1207F GPC.1615F GPC.2407H GPC.3215H GPC.3230H
Min. Cluster Size 3 Nodes 3 Nodes 3 Nodes 3 Nodes 3 Nodes
Max Cluster Size 12 Nodes 12 Nodes 12 Nodes 12 Nodes 12 Nodes
Per Node: Power Ranges 343W Typical – 490W maximum 378W Typical – 490W maximum 822W Typical – 1175W maximum 877W Typical – 1175W maximum 877W Typical – 1175W maximum
Power Delivery Continuous feeds 2x 208V 20 Amp Continuous feeds 2x 208V 20 Amp Continuous feeds 2x 208V 20 Amp Continuous feeds 2x 208V 20 Amp Continuous feeds 2x 208V 20 Amp
Operating Requirements Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz Input Voltage: 100-240V AC auto-range, Input Frequency: 50-60Hz
Power Diversity A & B UPS + Backup Power (generator) A & B UPS + Backup Power (generator) A & B UPS + Backup Power (generator) A & B UPS + Backup Power (generator) A & B UPS + Backup Power (generator)
Operating Environment Op Temp Range: 50° to 95°F (10° to 35°C) Op Humidity Range (non-condensing): 68° to 194°F (20° to 90°C) Op Temp Range: 50° to 95°F (10° to 35°C) Op Humidity Range (non-condensing): 68° to 194°F (20° to 90°C) Op Temp Range: 50° to 95°F (10° to 35°C) Op Humidity Range (non-condensing): 68° to 194°F (20° to 90°C) Op Temp Range: 50° to 95°F (10° to 35°C) Op Humidity Range (non-condensing): 68° to 194°F (20° to 90°C) Op Temp Range: 50° to 95°F (10° to 35°C) Op Humidity Range (non-condensing): 68° to 194°F (20° to 90°C)
Rough Dimensions Height: 1.70″
Width: 17.20″
Depth: 25.59″
Rack Units: 1U
Height: 1.70″
Width: 17.20″
Depth: 25.59″
Rack Units: 1U
Height: 3.47″
Width: 17.36″
Depth: 29.18″
Rack Units: 2U
Height: 3.47″
Width: 17.36″
Depth: 29.18″
Rack Units: 2U
Height: 3.47″
Width: 17.36″
Depth: 29.18″
Rack Units: 2U
Network Connections 2 x 10 or 25 Gbps SFP
1 x 1 GbE (TX)
2 x 10 or 25 Gbps SFP
1 x 1 GbE (TX)
2 x 10 or 25 Gbps SFP
1 x 1 GbE (TX)
2 x 25 Gbps SFP
1 x 1 GbE (TX)
2 x 25 Gbps SFP
1 x 1 GbE (TX)

Solution Licensing

Feature/Product Model
Licensing Model Consumption – Post Pay. Billed down to the day on Cluster capacity or other specificized unit of measure per product.  I.E. VM, Node, TiB.
Cluster Core Software AOS ULT (includes D.A.R.E and DRaaS)
Prism ULT
For a full list of features https://www.nutanix.com/products/legacy/software-options
In Cluster Discoverable Software
Nutanix Calm Per VM
Nutanix Flow Security Per Node
Nutanix Files in Cluster Per TiB (1 TiB included)
Nutanix Objects in Cluster Per TiB (2 TiB included)

Note: This list is the comprehensive list of available Nutanix software within our Consumption licensing program. Add-on packages such as Nutanix ERA (Nutanix Database NDB) is not compatible with this offering.

Sizing Guidance

Model GPC.1207F GPC.1615F GPC.2407H GPC.3215H GPC.3230H
OneNeck Benchmark Score* 24 46 72 145 159
VMs per Node 12 15 24 48 53
Largest Size VM B4 NUMA 8 vCPU 12 vCPU 12 vCPU + opt. vNUMA 16 vCPU

*OneNeck Benchmark Score – A VM average size is used as the baseline for setting a standard configuration to track price points across cloud solutions. This includes 2vCPU, 8 GB of RAM and 300 GB of storage.

The VM sizing was calculated across OneNeck’s study of our ReliaCloud customer base, and we’ve taken this VM sizing to give an approximate indicator of how many benchmark VMs we could safely fit into a 3-node cluster comprised of a specific node type.  Settings assume the follow parameters:

  • Per VM: 210 GiB cold and 90 Gib hot data
  • Cluster:  AHV, 4 to 1 vCPU : Physical core ratio, RF2 data resiliency, N+1 fault tolerance to 85% resource thresholds, in cluster scale out Prism Central and local data protection with snapshot schedule 4xhourly,7xdaily, 4xweekly, 1xmonthly.

Get In Touch

Call Us

For general inquiries, call: 855.663.6325

Immediate Assistance

Managed services support: 800.272.3077
Non-managed service support: 515.334.5755
Or visit our service desk:
Service Desk Portal